Executive Summary
Informations | |||
---|---|---|---|
Name | CVE-2022-30316 | First vendor Publication | 2022-07-28 |
Vendor | Cve | Last vendor Modification | 2022-08-05 |
Security-Database Scoring CVSS v3
Cvss vector : CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H | |||
---|---|---|---|
Overall CVSS Score | 6.8 | ||
Base Score | 6.8 | Environmental Score | 6.8 |
impact SubScore | 5.9 | Temporal Score | 6.8 |
Exploitabality Sub Score | 0.9 | ||
Attack Vector | Physical | Attack Complexity | Low |
Privileges Required | None | User Interaction | None |
Scope | Unchanged | Confidentiality Impact | High |
Integrity Impact | High | Availability Impact | High |
Calculate full CVSS 3.0 Vectors scores |
Security-Database Scoring CVSS v2
Cvss vector : | |||
---|---|---|---|
Cvss Base Score | N/A | Attack Range | N/A |
Cvss Impact Score | N/A | Attack Complexity | N/A |
Cvss Expoit Score | N/A | Authentication | N/A |
Calculate full CVSS 2.0 Vectors scores |
Detail
Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability. |
Original Source
Url : http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2022-30316 |
CWE : Common Weakness Enumeration
% | Id | Name |
---|---|---|
100 % | CWE-354 | Improper Validation of Integrity Check Value |
CPE : Common Platform Enumeration
Type | Description | Count |
---|---|---|
Os | 1 |
Sources (Detail)
Source | Url |
---|---|
MISC | https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-02 https://www.forescout.com/blog/ |
Alert History
Date | Informations |
---|---|
2022-08-06 05:27:15 |
|
2022-07-28 21:27:08 |
|